461 research outputs found

    Infarct-like myocarditis with coronary vasculitis and aneurysm formation caused by epstein–barr virus infection

    Get PDF
    Myocardial infection by Epstein–Barr virus (EBV) may manifest with inflammatory cardiomyopathy, coronary syndrome X, and rarely with infarct-like myocarditis. The aim of the report is to describe a case of myocardial EBV infection causing acute myocarditis with heart failure, necrotizing coronary vasculitis, and multiple left ventricular (LV) aneurysms. A 67-year-old woman presented with fever, chest pain, and heart failure. She underwent non-invasive cardiac studies including electrocardiography, 2D-echocardiography, cardiac magnetic resonance, hematochemical exams with Troponin T determination, and invasive studies including cardiac catheterization, coronary angiography, and LV endomyocardial biopsy. Five endomyocardial samples were processed for histology and immunohistochemistry for inflammatory cells characterization and detection of viral antigens. Two additional frozen samples were evaluated by real-time polymerase chain reaction for the presence of cardiotropic viral genomes. Routine laboratory tests revealed the presence of elevated white blood cells (17 000 103/μL) and increased Troponin T. Electrocardiogram showed sinus tachycardia with ST elevation in V2–V5. Two-dimensional echocardiography showed normal LV dimension with reduced LV contractility (LVEF = 40%) with mild pericardial effusion. Cardiac magnetic resonance revealed the presence of a micro-aneurism in the inferior LV wall, a diffuse oedematous imbibition of LV myocardium suggested by hyper-intensity of T2 mapping, and increased fibrosis as suggested by areas of late gadolinium enhancement signals. Coronary arteries were normal while several micro-aneurysms were observed at LV angiography. At histology, a lymphocytic myocarditis with necrotizing coronary vasculitis sustained by a positive real-time polymerase chain reaction for EBV, detectable in cardiomyocytes and inflamed intramural vessels by positive immunohistochemistry for EBV latent membrane protein 1 antigen, was observed. Myocardial EBV infection is an unusual cause of acute heart failure and cardiac aneurysms, increasing the risk of electrical instability, cardiac perforation, and sudden death

    Real-time optical dimensional metrology via diffractometry for nanofabrication

    Get PDF
    The ICN2 is funded by the CERCA programme/ Generalitat de Catalunya.Surface patterning technologies represent a worldwide growing industry, creating smart surfaces and micro/nanoscale device. The advent of large-area, high-speed imprinting technologies has created an ever-growing need for rapid and non-destructive dimensional metrology techniques to keep pace with the speed of production. Here we present a new real-time optical scatterometry technique, applicable at the mesoscale when optical inspection produces multiple orders of diffraction. We validate this method by inspecting multiple silicon gratings with a variety of structural parameters. These measurements are cross-referenced with FIB, SEM and scanning stylus profilometry. Finally, we measure thermally imprinted structures as a function of imprinting temperature in order to demonstrate the method suitable for in-line quality control in nanoimprint lithography

    CT attenuation analysis of carotid intraplaque hemorrhage

    Get PDF
    Background and Purpose: Intraplaque hemorrhage is considered a leading parameter of carotid plaque vulnerability. Our purpose was to assess the CT characteristics of intraplaque hemorrhage with histopathologic correlation to identify features that allow for confirming or ruling out the intraplaque hemorrhage. MATERIALS AND METHODS: This retrospective study included 91 patients (67 men; median age, 657 years; age range, 41-83 years) who underwent CT angiography and carotid endarterectomy from March 2010 to May 2013. Histopathologic analysis was performed for the tissue characterization and identification of intraplaque hemorrhage. Two observers assessed the plaque's attenuation values by using an ROI (≤1 and ≥2 mm2). Receiver operating characteristic curve, Mann-Whitney, and Wilcoxon analyses were performed. RESULTS: A total of 169 slices were assessed (59 intraplaque hemorrhage, 63 lipid-rich necrotic core, and 47 fibrous); the average values of the intraplaque hemorrhage, lipid-rich necrotic core, and fibrous tissue were 17.475 Hounsfield units (HU) and 18.407 HU, 39.476 HU and 48.048 HU, and 91.66 HU and 93.128 HU, respectively, before and after the administration of contrast medium. The Mann-Whitney test showed a statistically significant difference of HU values both in basal and after the administration of contrast material phase. Receiver operating characteristic analysis showed a statistical association between intraplaque hemorrhage and low HU values, and a threshold of 25 HU demonstrated the presence of intraplaque hemorrhage with a sensitivity and specificity of 93.22% and 92.73%, respectively. The Wilcoxon test showed that the attenuation of the plaque before and after administration of contrast material is different (intraplaque hemorrhage, lipid-rich necrotic core, and fibrous tissue had P values of .006, .0001, and .018, respectively). CONCLUSIONS: The results of this preliminary study suggest that CT can be used to identify the presence of intraplaque hemorrhage according to the attenuation. A threshold of 25 HU in the volume acquired after the administration of contrast medium is associated with an optimal sensitivity and specificity. Special care should be given to the correct identification of the ROI

    Integrated 3D Hydrogel Waveguide Out-Coupler by Step-and-Repeat Thermal Nanoimprint Lithography: A Promising Sensor Device for Water and pH

    Get PDF
    Hydrogel materials offer many advantages for chemical and biological sensoring due to their response to a small change in their environment with a related change in volume. Several designs have been outlined in the literature in the specific field of hydrogel-based optical sensors, reporting a large number of steps for their fabrication. In this work we present a three-dimensional, hydrogel-based sensor the structure of which is fabricated in a single step using thermal nanoimprint lithography. The sensor is based on a waveguide with a grating readout section. A specific hydrogel formulation, based on a combination of PEGDMA (Poly(Ethylene Glycol DiMethAcrylate)), NIPAAm (N-IsoPropylAcrylAmide), and AA (Acrylic Acid), was developed. This stimulus-responsive hydrogel is sensitive to pH and to water. Moreover, the hydrogel has been modified to be suitable for fabrication by thermal nanoimprint lithography. Once stimulated, the hydrogel-based sensor changes its topography, which is characterised physically by AFM and SEM, and optically using a specific optical set-up

    The current landscape of imaging recommendations in cardiovascular clinical guidelines: toward an imaging-guided precision medicine

    Get PDF
    The purpose of this article is to provide an overview on the role of CT scan and MRI according to selected guidelines by the European Society of Cardiology (ESC) and the American College of Cardiology/American Heart Association (ACC/AHA). ESC and ACC/AHA guidelines were systematically reviewed for recommendations to CT and MRI use in specific cardiovascular (CV) clinical categories. All recommendations were collected in a dataset, including the class of recommendation, the level of evidence (LOE), the specific imaging technique, the clinical purpose of the recommendation and the recommending Society. Among the 43 included guidelines (ESC: n = 18, ACC/AHA: n = 25), 26 (60.4%) contained recommendations for CT scan or MRI (146 recommendations: 62 for CT and 84 for MRI). Class of recommendation IIa (32.9%) was the most represented, followed by I (28.1%), IIb (24%) and III (11.9%). MRI recommendations more frequently being of higher class (I: 36.9%, IIa: 29.8%, IIb: 21.4%, III: 11.9%) as compared to CT (I: 16.1%, IIa: 37.1%, IIb: 27.4%, III: 19.4%). Most of recommendation (55.5%) were based on expert opinion (LOE C). The use of cardiac CT and cardiac MR in the risk assessment, diagnosis, therapeutic and procedural planning is in continuous development, driven by an increasing need to evolve toward an imaging-guided precision medicine, combined with cost-effectiveness and healthcare sustainability. These developments must be accompanied by an increased availability of high-performance scanners in healthcare facilities and should emphasize the need of increasing the number of radiologists fully trained in cardiac imaging

    Quantitative assessment of diffuse myocardial fibrosis in II-type diabetes mellitus patients using T1 mapping technique: preliminary data

    Get PDF
    In diabetic cardiomyopathy (DCM), ventricular remodelling consists in a progressive impairment of myocardial contraction (evolving from diastolic to combined diastolic-systolic dysfunction) occurring regardless of ischemic heart disease, hypertension or other macrovascular complications, which ultimately leads to heart failure. Early stages of DCM are asymptomatic and characterised by initial contractile disfunction and various degree of myocardial fibrosis, that may not be recognised by traditional cardiology tests. Our purpose was to detect myocardial fibrotic infiltration in DM-II patients by using T1-mapping technique with extracellular volume fraction (ECV) measurement

    Learning curve for laparoscopic cholecystectomy has not been defined: A systematic review

    Get PDF
    Background: Laparoscopic cholecystectomy is one of the most performed surgeries worldwide but its learning curve is still unclear. Methods: A systematic review was conducted according to the 2009 Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Two independent reviewers searched the literature in a systematic manner through online databases, including Medline, Scopus, Embase, and Google Scholar. Human studies investigating the learning curve of laparoscopic cholecystectomy were included. The Newcastle–Ottawa scale for cohort studies and the GRADE scale were used for the quality assessment of the selected articles. Results: Nine cohort studies published between 1991 and 2020 were included. All studies showed a great heterogeneity among the considered variables. Seven articles (77.7%) assessed intraoperative variables only, without considering patient's characteristics, operator's experience, and grade of gallbladder inflammation. Only five articles (55%) provided a precise cut-off value to see proficiency in the learning curve, ranging from 13 to 200 laparoscopic cholecystectomies. Conclusions: The lack of clear guidelines when evaluating the learning curve in surgery, probably contributed to the divergent data and heterogeneous results among the studies. The development of guidelines for the investigation and reporting of a surgical learning curve would be helpful to obtain more objective and reliable data especially for common operation such as laparoscopic cholecystectomy
    • …
    corecore